I METADATI DI QUESTO DOI SONO STATI AGGIORNATI IL: 2025-09-27 19:57
Titolo completo (Inglese)
Textile and Garment Magazine
Sottotitolo
списание Текстил и облекло
Marchio editoriale
Textile and Garment Magazine
Editore
SEUTGL
ISSN
1310-912X (Rivista Stampata)
2603-302X (Rivista Online)
Numero del volume
02
Numero del fascicolo
02
Designazione del fascicolo
papers
Data del fascicolo (YYYY/MM/DD)
2023/02/28
Titolo completo (Inglese)
DEVELOPMENT OF POLYMERIC BRAIDED STENTS
Sottotitolo
РАЗРАБОТВАНЕ НА ПОЛИМЕРНИ ОПЛЕТЕНИ СТЕНТОВЕ
Di (autore)
Affiliazione
University of Monastir, ENIM, Textile Materials and Processes Research Unit, Monastir, Tunisia, Professor
Affiliazione
University of Monastir, ENIM, Textile Materials and Processes Research Unit,Monastir, Tunisia , Professor
Affiliazione
University of Monastir, ENIM, Textile Materials and Processes Research Unit , Monastir, Tunisia , Professor
Affiliazione
Université de Haute-Alsace, Laboratoire de Physique et Mécanique Textiles, Mulhouse, France, Professor
Affiliazione
Groupe Européen de Recherche sur les Prothèses appliquées à la Chirurgie Vasculaire,Strasbourg, Fr , Professor
Numero di Pagine
11
Prima Pagina
54
Ultima Pagina
64
Lingua del testo
Bulgaro
Data di publicazione
2023/02/28
Descrizione principale (Inglese)
Metallic stents have been largely used over the last decades to treat vascular diseases like coronary artery or peripheral vessel stenosis. Although they remain the gold standard for vascular treatment, they are subjected to in-vivo complications such as corrosion, structural failure, fractures, and restenosis due especially to the material which is used. Polymeric stents were developed as an alternative to replace commercial metallic ones presenting several failures caused especially by the used metals. Among those materials, the polyethylene terephthalate (PET) have been used to develop stents since PET is suitable for several biomedical uses such as vascular prosthesis. Braiding technique was used since it provides flexible structures. In this paper methods and materials for the development and characterization of PET braided stents were given and the main results were highlighted. Results bring out that PET braided stents show very promising structural and mechanical performances comparing to metallic stents. They guarantee in particular a good flexibility and stability to cyclic loadings predicting their long term behavior. As a conclusion, PET-braided vascular stents show a huge potential to replace commercial stents but their manufacturing parameters should be carefully chosen. Keywords: Polymeric stents, non-biodegradable, PET, braiding.